Impact of Bluetooth Haptics Device Distraction on Mechanical Pain Thresholds Induced by PinPrick Stimulators

Purpose

This is a prospective, crossover study of healthy participants evaluating the mechanical pain threshold for weighted pinprick stimuli.

Conditions

  • Pain
  • Anxiety

Eligibility

Eligible Ages
Between 18 Years and 99 Years
Eligible Genders
All
Accepts Healthy Volunteers
Yes

Inclusion Criteria

  • Greater than 18 years of age - English speaking - Hearing intact

Exclusion Criteria

  • History of chronic pain or acute pain syndromes - Currently has nausea - Has hearing loss - Is pregnant - Is currently taking beta blockers, chronotropic heart medications, or opioids or other prescription pain medications

Study Design

Phase
N/A
Study Type
Interventional
Allocation
Randomized
Intervention Model
Parallel Assignment
Primary Purpose
Supportive Care
Masking
None (Open Label)

Arm Groups

ArmDescriptionAssigned Intervention
Experimental
Bluetooth Haptic Device (Experimental Frequency) + Needle Sham
Bluetooth Haptic Device with experimental vibrating frequency will be placed on the arm of the participant, with weighted pinpricks with fixed stimulus intensities will be applied.
  • Behavioral: Bluetooth Haptic Device (Experimental Frequency) + Needle Sham only
    Participants will have the Bluetooth Haptic Device with experimental Frequency placed on their arm and randomized to a series of 4 different vibration patterns/frequencies. Mechanical pain threshold (MPT) will be measure using custom-made weighted pinprick stimuli as a set of five pinprick mechanical stimulators with fixed stimulus intensities (flat contact area of 0.2mm diameter) with forces of 32, 64, 128, 256, and 512mN. The stimulators will be applied at a rate of 2s on, 2s off in a randomized order on participants' forearms until the first sensation of pain is reached and will then be done in descending order until the sensation of pain disappears. This procedure will be repeated five times of ascending and descending stimuli served as pinprick pain threshold on 1 arm at 4 different frequencies/patterns in the BHD.
Sham Comparator
Bluetooth Haptic Device (Control Frequency) + Needle Sham
Bluetooth Haptic Device with control vibrating frequency will be placed on the arm of the participant, with weighted pinpricks with fixed stimulus intensities will be applied.
  • Behavioral: Bluetooth Haptic Device (Control Frequency) + Needle Sham only
    Participants will have the Bluetooth Haptic Device with control frequency placed on their arm. They will be randomized to a series of 4 different vibration patterns/frequencies. Mechanical pain threshold (MPT) will be measure using custom-made weighted pinprick stimuli as a set of five pinprick mechanical stimulators with fixed stimulus intensities (flat contact area of 0.2mm diameter) with forces of 32, 64, 128, 256, and 512mN. The stimulators will be applied at a rate of 2s on, 2s off in a randomized order on participants' forearms until the first sensation of pain is reached and will then be done in descending order until the sensation of pain disappears. This procedure will be repeated five times of ascending and descending stimuli served as pinprick pain threshold on 1 arm at 4 different frequencies/patterns in the BHD.

Recruiting Locations

More Details

Status
Recruiting
Sponsor
Stanford University

Study Contact

Samuel Rodriguez, MD
650-723-5728
sr1@stanford.edu